Vendor - Dell
Product - iDrac
Ref |
Link |
Splunk Add-on |
na |
Add-on Manual |
https://www.dell.com/support/manuals/en-au/dell-opnmang-sw-v8.1/eemi_13g_v1.2-v1/introduction?guid=guid-8f22a1a9-ac01-43d1-a9d2-390ca6708d5e&lang=en-us |
Sourcetypes
sourcetype |
notes |
dell:poweredge:idrac:syslog |
None |
Index Configuration
key |
sourcetype |
index |
notes |
dell_poweredge_idrac |
dell:poweredge:idrac:syslog |
infraops |
none |
Filter type
MSG Parse: This filter parses message content
Options
Variable |
default |
description |
SC4S_LISTEN_DELL_POWEREDGE_IDRAC_TCP_PORT |
empty string |
Enable a TCP port for this specific vendor product using a comma-separated list of port numbers |
SC4S_LISTEN_DELL_POWEREDGE_IDRAC_UDP_PORT |
empty string |
Enable a UDP port for this specific vendor product using a comma-separated list of port numbers |
Verification
An active site will generate frequent events use the following search to check for new events
Verify timestamp, and host values match as expected
index=<asconfigured> (sourcetype=dell:poweredge:idrac:syslog sourcetype="UDP")
Product - CMC (VRTX)
Ref |
Link |
Splunk Add-on |
na |
Add-on Manual |
https://www.dell.com/support/manuals/en-us/dell-chassis-management-controller-v3.10-dell-poweredge-vrtx/cmcvrtx31ug/overview?guid=guid-84595265-d37c-4765-8890-90f629737b17 |
Sourcetypes
sourcetype |
notes |
dell:poweredge:cmc:syslog |
None |
Index Configuration
key |
sourcetype |
index |
notes |
dell_poweredge_cmc |
dell:poweredge:cmc:syslog |
infraops |
none |
Filter type
host or port
Note: CMC devices will also forward idrac events which will be matched using the MSG parser above.
Options
Variable |
default |
description |
SC4S_LISTEN_DELL_POWEREDGE_CMC_TCP_PORT |
empty string |
Enable a TCP port for this specific vendor product using a comma-separated list of port numbers |
SC4S_LISTEN_DELL_POWEREDGE_CMC_UDP_PORT |
empty string |
Enable a UDP port for this specific vendor product using a comma-separated list of port numbers |
Verification
An active site will generate frequent events use the following search to check for new events
Verify timestamp, and host values match as expected
index=<asconfigured> (sourcetype=dell:poweredge:cmc:syslog sourcetype="UDP")